Our Innovative Solution
The roof structure require significant design and engineering requirements in order to support the extremely large internal fridge and freezer ceilings and cooling units.
Due to fire compartment size restrictions, there was a requirement for an Internal concrete fire wall. Techspan achieved this using precast concrete.
Varied bay spacings to match pallet racking layout and maximise the efficiency of the internal layout.
Slab design to incorporate setdowns for dock levelers and an insulated floor in the fridge and freezer sections.
Massive 15.0m x20.0m cantilever awning to facilitate all-weather loading and unloading of trucks – efficient material handling.
Varied wall cladding colours provide a cost effective architectural appeal/design aesthetic.