New Wind Assessment Standards – What You Need To Know.

The new National Construction Code (NCC) released in September 2022 included an update to the Wind Assessment Standards.  

From our initial consultation to design and engineering through to material selection and manufacture, Techspan is committed to ensuring that our client projects not only meet the new standards but also deliver quality, practical, efficient and enduring infrastructure that maximises productivity, safety, security and accessibility. Our reputation is unrivalled when it comes to listening to customer needs, attention to detail throughout every stage of a project and standing by our quality workmanship.

What standards apply to your project?

Currently the two standards that apply are:

  • AS 4055:2012 (most commonly applied to residential housing — gives a wind rating)
  • AS/NZS 1170.2:2011 (used when the geometric limits of AS 4055 are exceeded, e.g. roof height over 8.5m — gives a design wind speed).


Further, the following contributing factors are considered to formulate results to determine what is required with your particular project:

  • Wind Region — based on updated standards available for different regions of Australia (see region map below)
  • Shielding — what is considered as ‘shielding’ of the structure by adjacent structures and trees (AS 4055 only)
  • Terrain — consideration to smoothness or roughness of the terrain due to trees and other structures. For AS 4055 this includes considering terrain within 500 metres in all directions. AS/NZS 1170.2 includes an averaging distance of 500 metres or 40 times average of the project roof height plus a lag distance, whichever is greater.  
  • Topography — considers any significant cross sections of a hill, any site where it is located on a hill and site slope.

What changes have been made to wind assessment standards?

The new standards will be aligned more closely to each other. Some key changes which may impact the ratings for your projects are as follows: 

AS 4055:2021 (Wind loads for housing)

  1. The geometric limitations of AS 4055 have been clarified with the introduction of the term “averaged ground level”, defined as the natural ground level excluding earthworks where earthworks are minor, or through the modified land where the earthworks are major. This may lead to more projects sitting outside the limitations of AS 4055 and therefore coming under AS/NZS 1170.2:2021.  
  2. Terrain Category 1.5 has been removed. Bodies that fit into this category are now in TC1.
  3. Some wind region zoning has changed. Most notably for South East Queensland, Toowoomba is now in Region B, not Region A.
  4. Calculation of topographic class was previously taken as the maximum slope through the closest peak. It now explicitly states that the slope must run through the project site.  This brings AS 4055 more in line with AS/NZS 1170.2 and better takes into account conditions at the project site.
  5. A subsequent revised wind classification table (refer below)
  6. Equivalent wind ratings from AS/NZS 1170.2 are now allowed for the purpose of specifying building products (eg windows, doors and cladding).

AS/NZS 1170.2:2021  (Structural design actions, Part 2: Wind actions)

  1. For wind regions B2, C & D, a newly introduced climate change multiplier (Mc) will account for possible changes in climate affecting extreme winds over the design life of buildings. This may be adjusted in future, depending on observed or predicted trends.
  2. The wind regions map has changed and regions A0, B1 (including Toowoomba) and B2 have been introduced (see updated map below)  
  3. Wind direction multipliers have been revised for all wind regions in Australia.
  4. Terrain category TC1.5 has been removed (as per AS 4055) and multipliers for TC1 have been slightly reduced.


Design Wind Speed Calculations According to AS1170.2:2021 (Updated Code)


Based on structure lifespan 25 years / Max av. height 10m Terrain Category 2 for all calculations 
AUSTRALIAN WIND REGIONULTIMATE REGIONAL WIND SPEED (km/h)IMPORTANCE LEVELDESIGN WIND SPEED (km/h)
Region A01621148
  2154
  3162
Region A1 to A51621148
  2154
  3162
Region B12051164
  2177
  3194
Region B22051163
  2176
  3192
Region C2381192
  2207
  3255
Region D2881226
  2246
  3271

Will the changes affect project cost?

There are likely to be variations in results from the old to new standards, some more favourable (costing less for the build), and others not so. The goal of the changes is to improve the system, making wind assessments more accurate (with AS 4055 becoming more consistent with AS/NZS 1170) and therefore safer and more enduring structures. 

In short, the requirements and costs related to your project will be determined once your location, wind region, terrain category and importance level are determined.


How Techspan Can Help

When you begin the design consultation at Techspan, location is one of the early questions we ask. We consider your location with respect to Wind Region, Terrain Category and Importance Level and factor this into the design and engineering stages to ensure that your project meets the required standard, in accordance with AS/NZS 1170.2.

In some cases, local councils may also have specific requirements that will also be taken into consideration. 

It is extremely important to classify every structure on a case-by-case basis and assess every location individually. If wind is not properly discussed or considered in the design process it could be hazardous and affect the longevity of your structure. 

Safety and Structural Integrity are key considerations within our design philosophy here at Techspan and ensuring that all Techspan projects are ‘structured to work’ for many years to come. 

With over 20 years’ experience in the industry and hundreds of aviation, rural, agribusiness, mining, commercial, industrial and school infrastructure projects delivered, our team are here to make the process of achieving your new project simple.

Council Approvals Consultant Roles

The council approvals process can involve working with several different consultants to prepare the right documentation for your application. To help make this process run smoother, we’ve put together a summary of some of the key consultants you might need to work with for your new TechSpan steel building.

What is the PCA and what is their role?

The main roles of the Principal Certifying Authority (PCA) include:

  • Ensure compliance with the development consent and the construction certificate or the complying development certificate;
  • Ensure compliance with all the relevant development conditions;
  • Ensure compliance with the Building Code of Australia;
  • Carry out all the required inspections associated with the building works;
  • Issue the occupation certificate when all works are completed.

What is a Town Planner?

A town planner works on behalf of the developer or landowner and can advise on and assess your development idea and plans. Town planners can develop a strategy and help put together reports to ensure the best outcome in the council approval process.


What is an Architectural Draftsman?

An architectural draftsman will turn the architectural concepts into drawings and plans that can be submitted as part of your approvals process.


What is a Structural Engineer?

A structural engineer’s job is to ensure that your building design is structurally sound. They will analyse the properties of your structure, test the behaviour and durability of materials used in their construction, and design and supervise the construction of all types of buildings to ensure they will stand up to the conditions and use they’re intended for.


What is a Civil Engineer?

Civil engineers design and plan the construction of dams, bridges, pipelines, sewage systems, roads and other civil projects. They also analyse the likely behaviour of soil and rock at the site of your proposed development to ensure your new building and its foundations will be structurally sound.


What is the Role of A Builder?

A builder oversees and coordinates the construction of your new building, and can manage the entire project. The builder is responsible for managing schedules, organising other trades, managing quality and compliance, managing the site, and ensuring WHS rules are enforced. There are strict safety regulations including wearing protective equipment, and ensuring the site is safe for other necessary site visitors that builders must comply with.


What is a Private Certifier?

Registered certifiers assess and determine applications for development certificates for building and subdivision work. Most certifiers are qualified building surveyors who can issue development certificates for building work, be appointed as the principal certifier, and carry out inspections.


What is TechSpan’s Role?

TechSpan does not take on the role of the builder or principal contractor. TechSpan is responsible for the design, structural engineering, and the supply and installation of the structural steel and cladding package. Our scope includes all structural steel, cladding, doors, windows and rainwater goods to ground level. Techspan can also help with civil and concrete engineering design, and connect you with our ever-growing network of SmartPoint verified consultants and tradespeople to support you with installation, as needed.

Building Classes Explained

All buildings in Australia come under the Building Code of Australia (BCA), which contains regulations and requirements that the building must meet.

These requirements vary depending on what you’re planning to use the building for. These different uses make up the building classes.

There are ten main building classes (some with multiple sub-classes) within the BCA. Typically, TechSpan buildings come under one of the four classes listed in more detail at the end of this article.

Building Classes Overview

Class 1.

Class 1a – A single dwelling being a detached house, or one or more attached dwellings, each being a building, separated by a fire-resisting wall, including a row house, terrace house, townhouse or villa unit.

Class 1b – A boarding house, guest house, a hostel or the like with a total area of all floors not exceeding 300m2, and where not more than 12 reside and is not located above or below another dwelling or another Class of building other than a private garage

Class 2.

A building containing 2 or more sole-occupancy units each being a separate dwelling.

Class 3.

A residential building, other than a Class 1 or 2 building, is a commonplace of long term or transient living for a number of unrelated persons. Example: boarding-house, hostel, backpackers accommodation or residential part of a hotel, motel, school or detention centre.

Class 4.

A dwelling in a building that is Class 5, 6, 7, 8 or 9 if it is the only dwelling in the building.

Class 5.

An office building that is used for professional or commercial purposes, excluding buildings of Class 6, 7, 8 or 9.

Class 6.

A shop or other building for the sale of goods by retail or the supply of services direct to the public. Example: café, restaurant, kiosk, hairdressers, showroom or service station.

Class 7.

Class 7a – A building which is a car park.

Class 7b – A building which is for storage or display of goods or produce for sale by wholesale.

Class 8.

A laboratory or a building in which a handicraft or process for the production, assembling, altering, repairing, packing, finishing or cleaning of goods or produce is carried on for trade, sale or gain.

Class 9.

A building of a public nature.

Class 9a – A health care building, including those parts of the building set aside as a laboratory.

Class 9b – An assembly building, including a trade workshop, laboratory, or the like, in a primary or secondary school, but excluding any other parts of the building that are of another class.

Class 9c – An aged care building.

Class 10.

A non-habitable building or structure.

Class 10a – A private garage, carport, shed or the like.


What Building Class is My New TechSpan Building?


Class 7b — Storage Buildings

A building which is for storage or display of goods or produce for sale by wholesale.

Examples of TechSpan buildings that would fall into this category are showrooms and warehouses.


Class 8 — Processing & Factory Buildings

A laboratory or a building in which a handicraft or process for the production, assembling, altering, repairing, packing, finishing or cleaning of goods or produce is carried on for trade, sale or gain.

Examples of TechSpan buildings that would fall into this category are factory, packing, product, manufacturing and workshop sheds.


Class 9b — Assembly Buildings

An assembly building, including a trade workshop, laboratory, or the like, in a primary or secondary school, but excluding any other parts of the building that are of another class.

An example of TechSpan buildings that would fall into this category is school COLAs.


Class 10a — Carports & Sheds

A private garage, carport, shed or the like.

Examples of TechSpan buildings that would fall into this category are multipurpose farm sheds and private machinery sheds.

We’re Here to Help

If you are unsure which class best applies to a building you are planning, the expert team at TechSpan can help you. Get in touch with our design consultants to get started.

Council Approvals Guide

The entire council approvals process can be daunting and confusing—especially if this is your first time building a shed.

Do you need approval at all? How do you go about getting approval?
What are the main things you’ll need, and in what order?

To try and help the approvals process run smoother, we’ve put together a guide that outlines what you need to know, step-by-step, to streamline the council approvals process for your new TechSpan steel building.

The approvals process runs hand in hand with the design process. The building design is impacted by the Building code of Australia and local council criteria, and the council approval pathway is dependent on building design. 

The first thing you will need to determine is what class your new building will fall under. This will affect the approval pathway you follow and the documentation you will require.

Building Classes

There are ten building classes set out in the Building Code of Australia that each structure is categorised into. TechSpan buildings typically fall into one of the four classes outlined below.

To see the full list of all building classes, check out our building classes overview.


Class 7b — Storage Buildings

A building which is for storage or display of goods or produce for sale by wholesale.

Examples of TechSpan buildings that would fall into this category are showrooms and warehouses.


Class 8 — Processing & Factory Buildings

A laboratory or a building in which a handicraft or process for the production, assembling, altering, repairing, packing, finishing or cleaning of goods or produce is carried on for trade, sale or gain.

Examples of TechSpan buildings that would fall into this category are factory, packing, product, manufacturing and workshop sheds.


Class 9b — Assembly Buildings

An assembly building, including a trade workshop, laboratory, or the like, in a primary or secondary school, but excluding any other parts of the building that are of another class.

An example of TechSpan buildings that would fall into this category is school COLAs.


Class 10a — Carports & Sheds

A private garage, carport, shed or the like.

Examples of TechSpan buildings that would fall into this category are multipurpose farm sheds and private machinery sheds.

Planning Approval Pathways

As different projects will require different approval pathways before you get started down any particular pathway, it’s best to have the proposed building reviewed. This will ensure you’re heading down the right track. TechSpan is able to offer a review to determine the best approval pathway for your new TechSpan building. You can contact our expert team for more information.

Once you have determined the building class which applies to the structure you’re planning, you need to determine the appropriate approval pathway that you will need to follow. These are the different ways that you can apply for approval to construct your project either through a private town planner and certifier or directly with your local council.

The three different approval pathways that may apply to TechSpan buildings are: 
Exempt Developments, Complying Developments (CDC), and buildings that require Development Approval (DA). 

(This information is specific to the planning approval pathways in NSW. Other states will vary slightly in the naming of the different pathways and some of the processes & requirements.)

Exempt Developments

Exempt developments cover minor, low impact developments that are built on rural properties. If your building meets specific development standards, any further planning or building approval is not needed. This means any construction that does not require a full assessment by the council can be done faster, and with lower costs.

Exempt development standards apply to many farm sheds and buildings less than 200m2.


Complying Developments

A Complying Development Certificate (CDC) combines planning and construction approval into one fast-tracked process that does not require a development application to your local council. Many commercial and industrial developments are eligible for this pathway, as long as the development complies with the Building Code of Australia and any local criteria.

Documentation You Will Need:

If you’re new TechSpan building is eligible for a CDC, you will need to provide the following to your certifier:

  • Architectural design
  • Geotech & Survey
  • Engineering design for the civil and structural works
  • Plans for Stormwater retention and runoff
  • Carparking and traffic flow studies
  • Landscaping plans
  • Fire escape and retention plans
  • BCA Section J6 Certificate
  • Section 68 Approval Certificate for local council

Sometimes, depending on the zoning and specific local council requirements additional documentation may also be required.


Development Approval

A Development Application (DA) is required for more complex projects and where the development needs to be assessed under the Environmental Planning and Assessment Act 1979. You will need to compile and submit standard application forms, supporting technical documents and plans to your local council for assessment.

The NSW government and local council requirements for a DA are comprehensive and complex. TechSpan can assist you in preparing and submitting all the information to the council, and help avoid delays.

Prior to lodging a development application (DA) with your local council, you will need to carefully review any planning policies that apply to your land, in order to prepare your plans and supporting documentation. To see what local environmental planning constraints, applicable planning policies and permissible uses apply to your land or property, you can use the New South Wales Government Planning Portal.

If your application is approved, a schedule of conditions will be issued with the notice of determination. The development consent is structured to assist in the project management of the development and these conditions must be complied with. The conditions should be read in conjunction with the stamped approved plans.

Documentation You Will Likely Need:

If you’re new TechSpan building requires DA and a construction certificate, you will need to provide the following to your local council (or the private certifier assisting you):

Development Application (DA)

  • Architectural design plans:
    • Site plan
    • Roof plan
    • Floor plan
    • Elevations
    • Building sections
    • Erosion Sedimentation
    • Window & Door Schedule
  • Geotech & Survey
  • Landscaping plans
  • Statement of Environmental Effect (SEE)
  • Wildlife Impact studies
  • Development budgets


Construction Certificate

  • Engineering design for the civil and structural works
  • Plans for Stormwater retention and runoff
  • Fire escape and retention plans
  • Section J Reports
  • Waste Management Statement
  • Section 68 Approval Certificate for local council


Sometimes, depending on the zoning and specific local council requirements additional documentation may also be required.


What is the Development Application Process?

Where a Development Application (DA) is required, the usual steps are:

  1. Site Analysis & Constraints: Techspan can assist in undertaking appropriate site analysis and assessments to understand any site constraints, such as flooding, bushfire risk or soil/slope constraints.
  2. Plans/Drawings: Creating appropriate plans/drawings for your development proposal which accommodate all site constraints, as best as practical, is the next step in the process.
  3. Review & Endorsement: Once plans are complete, your town planner will organise the appropriate review and endorsement from government authorities, such as the Water Authority, as this is usually required prior to the lodgement of your DA.
  4. Preparation for lodging: At the same time your plans are being endorsed by other authorities, your town planner prepares the application in readiness for lodging with Council. This would normally include the preparation of a Statement of Environmental Effects (SoEE) to support your development, which addresses the potential impacts your development may have on the environment and surrounding neighbours.
  5. Application Lodged: your town planner will regularly communicate with Council to track the progress of the application, in an effort to ensure Council has sufficient information to allow a timely assessment. Your town planner will update clients regularly throughout this process.
  6. Additional Information (if required): Should Council require any additional information throughout the assessment process, your town planner will liaise with you to provide a rapid response and solution to Council’s request.
  7. Approval: Once the DA is approved by Council, no works can commence until a Construction Certificate is obtained.

Is my development guaranteed to be approved?

No. There is no guarantee that Council will issue a Development Consent once an application is lodged. Prior to an application being lodged with the council, and based on our experience and knowledge of Council and their individual planning controls, we will discuss with you if we feel that the proposal is outside of Council’s requirements. We can discuss any alternative options you have.

What if the council doesn’t like what I am proposing in my application?

Council will normally advise in writing if they are not completely satisfied with what is being proposed. This gives you a chance to either make changes to the proposal or talk to an Assessing Officer about how to make the proposal work. If the Assessing officer feels that the amendments being requested are not consistent with Council’s planning controls, this can be negotiated with the Assessing Officer.

What is a Construction Certificate?

Once development consent is granted, a Construction Certificate is required to be obtained prior to the commencement of building works. This can be issued after plans and specifications of the proposed works have been assessed to comply with the Building Code of Australia and conditions of the development consent have been satisfied.

Are inspections mandatory?

Yes. The Environmental Planning & Assessment Regulation (EP&A Reg) sets out the number of mandatory inspections for all types of buildings.

The Principal Certifying Authority (PCA) must advise the owner what inspections are required to be carried out by the PCA. Where an inspection by a third party, such as an engineer, is required, the PCA will request written confirmation in the form of a report or certificate to verify that the inspection was carried out and that work satisfies any applicable standards.


Approval Documentation Requirements Overview

Documentation RequiredExempt DevelopmentComplying DevelopmentDevelopment Application
Architectural Design
Geotech & Survey
Engineering Design
Stormwater Retention & Runoff Plans
Carparking and traffic flow studies
Landscaping plans
Fire escape and retention plans
BCA Section J6 Certificate
Section 68 Approval Certificate for local council
Statement of Environmental Effect (SEE)
Wildlife Impact studies
Development budgets
Section J Reports
Waste Management Statement

We’re Here to Help

While the process sounds long and complicated (and in some circumstances, it can be) TechSpan have experience in dealing with local council approvals throughout NSW and will assist where possible throughout the process. We can connect you with the right consultants [link to consultant article] at the right stage of your project.

If you’d like more information about TechSpan’s rates to undertake various components of the council approvals process, our expert team is here to help!

Farm Shed Roofline Options

Are you considering building a new farm shed? One of the earliest decisions you’ll need to consider is what roofline best suits your needs. There are several roofline options, and each works best for specific applications. We’ll go over each of the main roof pitch options with some information on each, to help you decide.

Standard Gable Roof

Probably the most common roof shape, a standard gable roof has two slopes that meet at a raised centre peak.

A gable roof helps to keep the inside of the shed cooler, by allowing hot air to rise to the centre space. It’s also an excellent roofline to choose if you want to add ridge vents, as it can create a convection effect, drawing fresh air in from the sides as the warmer air escapes through the ridge vents. The rain can run off to gutters on both sides of the structure. However, this may not be the best roofline option for your shed if you are in a high-wind location.

Steep Pitch Gable Roof

A steep pitch gable is essentially the same as the gable roof, but the two slopes are on a steeper angle. This is a good option for grain sheds to maximise the stacking height available. Even more so than a standard gable roof, this design may not be suitable for high-wind locations. A steep pitch gable roof might also be a good option for you if you are in an area with high snowfall or a snow loading requirement as the steep pitch allows snow to run off quickly.

Skillion or Single Pitch Roof

A skillion roof is one without a centre peak and with a single slope. This roofline is a pretty common choice for farm sheds, as well as sheds in industrial areas.

It can create a modern, sleek look, while also having some practical benefits. With a single slope, the rain only runs off one side of your shed, which means less guttering & downpipes. It’s also a good option if you’re considering adding solar panels to your shed. But, unlike the gable roof options, a skillion or single pitch roof has less of a convection effect and has no space for ridgeline vents to help regulate airflow and temperature.

Curved Roof

A curved roof might be a good option if you’re looking for something that has a significant visual impact. While we most commonly see these used in industrial projects and school COLAs, they are a possibility for any highly-visible shed.

Essential Considerations When Choosing a Roof Option

So, how do you choose the roof shape that best suits your farm shed? There are five key considerations to keep in mind when trying to determine which is best for your application and location.


Wind Speed

Steep pitches and high winds aren’t the best combination. If you’re building your shed in a high-wind area, a steep roof will require more structural support and reinforcement to withstand those winds. Our expert design consultants can help you establish which wind rating zone your shed will be located in, and the best roofline and structure for that location.


Rain & Run-Off

The angle of your roof will affect how quickly any rain runs off, and the direction the run-off goes. If you’re in an area that experiences frequent heavy rain, you might need a slightly steeper pitch to handle the rainfall. If you’re hoping to capture that rainfall into a rainwater tank, you’ll also want to consider the best way to do that. A skillion roof might be a good option, as only one side will require guttering and downpipes. It’s also worth checking in whether you may need to meet snow load requirements in your location as well.


Interior Height

If you need a little extra interior height for taller machinery or storage space, make sure you consider that when determining the roofline for your shed. A gable roof will give you more height in the centre of your shed, whereas a single-pitch roof will provide you with extra height on one side, and a little less height on the other. The extra height on one side of a skillion roof might be useful if you’re planning on emptying a tipper of grain into the shed, but the centre height paired with ridge vents might be a lifesaver for a stockyard cover in a hot climate.


Ventilation

Depending on how you plan to use your shed, and it’s location, ventilation is a factor to consider when determining the best roofline for your needs. A gable roof will allow for ridge vents creating plenty of ventilation, while a single pitch roof might require ‘whirlybird’ ventilation to ensure there is enough airflow. Our team can help you decide which option will work best in your location for your requirements.


Aesthetics

Last (but not least) is deciding how you want your shed to look. If your shed is in a particularly visible location, you might want a little something to make it look more professional. Our expert team of design consultants can help you develop a shed design that not only works well for your needs but looks great too.